NI Counter Pulse Element

Modified on 2018/08/02 23:10 by Administrator — Categorized as: Communications

Summary

Element Icon NI Counter Pulse
Info
Category: Communication AddIn: AddIn_NI
Creator: OkazoLab Scope: Parent event
Owns Snippets: None Usage: Snippets

Properties

NameDescription                              ConstraintsTypeOn
runtime
change
Settings
NI Counter Channel        Defines the selected counter channel on the NI board                String         
Working Mode        Defines a working mode for the element                stNIPo..         
Output
Is Idle Low        Defines the idle state (low or high) for the generated pulses                Boolean         
Preface Duration        Defines the duration (ms) of the guarantied zero preface interval for the TTL or Pulse signals. Increase the preface duration marginally, if your recording hardware does not detect port signals. Note that a non-zero preface delays the onset of the actual signal.                Double         
Pulse Duration        Duration of a single output pulse in ms. The value is applied only if the Pulse signal profile is selected                UInt64         
Interpulse Duration        Defines a duration of the inter-pulse interval in ms. The value is applied only if the Pulse  signal profile is selected                clTime         
Pulse Number        Defines a number of pulses in the pulse train. The value is applied only if the Pulse signal profile is selected                Int32         
Send Output Now        Runtime action initiating an instant output communication through the port. Call this action in snippets by 'SendNow=true;', but only if the element works in the 'Manual I/O' mode.                Boolean         
Runtime Status
Triggering Time        Indicates the local event time of the last element triggering. Triggering occurs only in the 'Input Detection' working mode.                clTime         
Control
Is Enabled        If set to false the element is completely omitted when the experiment is run                Boolean         
Title        Title of the element                String         

NI Counter Pulse Element allows sending a single pulse or pulse train through the output counter channel on the National Instruments DAQ cards.

Description

...

Snapshots

Snapshot 1

Snapshot 1

Snapshot 2

Snapshot 2

Practical Use

...

Technique 1

  1. Step 1
  2. Step 2
    ...
    === Technique 2 ===
  3. Step 1
  4. Step 2
    ...

     // Check the trial outcome. Result and RT just other user variables
    
    // insert code snippet here..
               
    ...
    == Notes ==
    ...
  5. Insert Notes here..
  6. Insert Notes here..



NI Counter Pulse element allows sending a single pulse or pulse train through the output counter channel on the National Instruments DAQ cards.