Summary

Element Icon BioPlux Buffer
Info
Category: Signal Acquisition AddIn: AddIn_BioSignalPlux
Creator: OkazoLab Scope: Experiment
Owns Snippets: None Usage: Snippets

Properties

NameDescription                              ConstraintsTypeOn
runtime
change
BioPlux Settings
BioPlux Device        Selects a BioPlux device for signal acquisition                String         
Chunk Size                        Int32         
Sampling Rate        Defines a sampling rate (Hz) of data acquisition for all channels.                Double         
Sample Resolution        Defines the sample resolution in bits                Int32         
Runtime Control
Set DOut Now        Runtime command that sets the BioPlux digital output either to true (1) or false (0). In order to invoke the command, assign a boolean (true, false) or numerical value (1,0) to this property at runtime.                Object         
Reset Signals Now        Runtime commands that resets the signal buffers and data acquisition                Boolean         
Signal Generator
Signal Source        Defines a source for the signal. The emulated rhythmes can be used for offline validation of the chosen analysis settings                enEmul..         
Emulated Sampling Rate        Defines the emulation sampling rate (samples per second), when data is generated or streamed from a file.                Double         
Primary Frequency        Defines the frequency of the primary rhythm in the generated signal, in Hz. Assign the zero to exclude the primary frequency from the generated signal.                Double         
Secondary Frequency        Defines the frequency of the secondary rhythm in the generated signal, in Hz. The secondary frequency magnitude is a half of the primary frequency magnitude. Assign the zero to exclude the secondary frequency from the generated signal.                Double         
Noise Level        Defines the noise level (in % to the norm magnitude of the primary frequency). The noise is added to the generated signal. Assign the zero the exclude the noise from the generated signal.                Double         
External Datafile        Opens the dialog for selecting a data file containing a stream of double numbers representing a signal. If a file name without a path is defined, the data file will be picked up in the location of the experiment file.                String         
Channel Configuration
Selected Channels        Defines what signal channels are selected for acquisition within EventIDE. Selected channels are registered in the EventIDE signal pool at runtime and become available for the signal analysis elements.                IList         
Selected Channel Count        Indicates how many signal channels are currently selected for acquisition                Int32         
Total Channel Count        Indicates how many signal channels are available for acquisition in the total                Int32         
Buffer Size        Defines the size (in samples) of a circular buffer that stores incoming signal data.                Int32         
Control
Is Enabled        If set to false the element is completely omitted when the experiment is run                Boolean         
Title        Title of the element                String         

BioPlux Buffer Element enables real-rime acquisition with the BioPlux sensors.

Description

...

Snapshots

Snapshot 1

Snapshot 1

Snapshot 2

Snapshot 2

Practical Use

...

Technique 1

  1. Step 1
  2. Step 2
    ...
    === Technique 2 ===
  3. Step 1
  4. Step 2
    ...

     // Check the trial outcome. Result and RT just other user variables
    
    // insert code snippet here..
               
    ...
    == Notes ==
    ...
  5. Insert Notes here..
  6. Insert Notes here..

 