Summary
|
BioPlux Buffer
|
Info |
Category: |
Signal Acquisition |
|
AddIn: |
AddIn_BioSignalPlux |
Creator: |
OkazoLab |
|
Scope: |
Experiment |
Owns Snippets: |
None |
|
Usage: |
Snippets |
Properties
Name | Description | Constraints | Type | On runtime change |
---|
BioPlux Settings |
BioPlux Device | Selects a BioPlux device for signal acquisition | | String | |
Chunk Size | | | Int32 | |
Sampling Rate | Defines a sampling rate (Hz) of data acquisition for all channels. | | Double | |
Sample Resolution | Defines the sample resolution in bits | | Int32 | |
Runtime Control |
Set DOut Now | Runtime command that sets the BioPlux digital output either to true (1) or false (0). In order to invoke the command, assign a boolean (true, false) or numerical value (1,0) to this property at runtime. | | Object | |
Reset Signals Now | Runtime commands that resets the signal buffers and data acquisition | | Boolean | |
Signal Generator |
Signal Source | Defines a source for the signal. The emulated rhythmes can be used for offline validation of the chosen analysis settings | | enEmul.. | |
Emulated Sampling Rate | Defines the emulation sampling rate (samples per second), when data is generated or streamed from a file. | | Double | |
Primary Frequency | Defines the frequency of the primary rhythm in the generated signal, in Hz. Assign the zero to exclude the primary frequency from the generated signal. | | Double | |
Secondary Frequency | Defines the frequency of the secondary rhythm in the generated signal, in Hz. The secondary frequency magnitude is a half of the primary frequency magnitude. Assign the zero to exclude the secondary frequency from the generated signal. | | Double | |
Noise Level | Defines the noise level (in % to the norm magnitude of the primary frequency). The noise is added to the generated signal. Assign the zero the exclude the noise from the generated signal. | | Double | |
External Datafile | Opens the dialog for selecting a data file containing a stream of double numbers representing a signal. If a file name without a path is defined, the data file will be picked up in the location of the experiment file. | | String | |
Channel Configuration |
Selected Channels | Defines what signal channels are selected for acquisition within EventIDE. Selected channels are registered in the EventIDE signal pool at runtime and become available for the signal analysis elements. | | IList | |
Selected Channel Count | Indicates how many signal channels are currently selected for acquisition | | Int32 | |
Total Channel Count | Indicates how many signal channels are available for acquisition in the total | | Int32 | |
Buffer Size | Defines the size (in samples) of a circular buffer that stores incoming signal data. | | Int32 | |
Control |
Is Enabled | If set to false the element is completely omitted when the experiment is run | | Boolean | |
Title | Title of the element | | String | |
|
BioPlux Buffer Element enables real-rime acquisition with the
BioPlux sensors.
Description
...
Snapshots
Snapshot 1
| Snapshot 2 |
Practical Use
...
Technique 1
- Step 1
- Step 2
...
=== Technique 2 === - Step 1
- Step 2
...
// Check the trial outcome. Result and RT just other user variables
// insert code snippet here..
...
== Notes ==
... - Insert Notes here..
- Insert Notes here..