Page History: MC DAQ Port Element
Compare Page Revisions
Page Revision: 2011/11/16 14:08
|
New Element
|
Info |
Category: |
|
|
AddIn: |
Base Elements |
Creator: |
OkazoLab Team |
|
Scope: |
Parent Event |
Owns Snippets: |
no |
|
Usage: |
Runtime Screen,Snippets |
The element allows/is capable of doing something in experiments
Description
Short description
Snapshots
Snapshot 1
| Snapshot 2 |
Practical Use
Technique 1
- Step 1
- Step 2
Technique 2
- Step 1
- Step 2
// Check the trial outcome. Result and RT just other user variables
// insert code snippet here..
Element actions aligned with different epochs of the parent event
Epoche | Actions |
---|
Initialized |
Rendered |
Activating |
Activated |
Running |
Deactivated |
Deinitialized |
Notes
Insert Notes here..
Properties
Generic Properties
Name | Description | Attributes | Value Type | Proxy Reflex |
---|
Control |
Test post | | | DesignTimeAction | |
MC DAQ Board number | Number of the MC DAQ card in the system | | Int32 | |
+=== Properties inherited from clParallelPortElement ===
Inherited properties of clParallelPort
Name | Description | Constraints | Value Type | Upon Runtime Change |
---|
Port Settings |
Working Mode | Defines a working mode for the element.Select the 'Output on event onset' mode for sending signals synchronously with an onset of the parent event,or 'Triggering on input' mode for catching the particular pattern in port input. For custom reading/writing scenarios use the 'Manual IO' mode, in which port communications can be controlled by your code. | | Int32 |
Output |
Test Output | Sends a test output signal through the port using the selected signal profile and the current Output Value. | |
Signal Profile | Defines the time-amplitude profile of the output signal. The 'Level Change', 'Pulse' and 'TTL' profiles are available. Last two can be used to send the EEG triggers. | | Int32 | |
Preface Duration | Defines the duration (ms) of the guarantied zero preface interval for the TTL or Pulse signals. Increase the preface duration marginally, if your recording hardware does not detect port signals. Note that a non-zero preface delays the onset of the actual signal. | | Double | |
Pulse Duration | Duration of an output pulse in ms. The value is applied only, if the Pulse signal profile is selected. | | UInt64 |
Output Value | Value to be sent through the port. Can be defined in integer or binary format, e.g. Output='01010000'; or Output=255; | | clBinaryInteger |
Send Now | Runtime command that that initiates an instant transfer of the current output value through the port. Manual command calls at runtime are only required, if the element works in the Manual I/O mode. | | Boolean | Execute the command by assigning true in code: SendNow=true; |
Input |
Test Input | Open a input monitor window showing real-time port input with the current settings. Use it for testing at designtime. | |
Input Value | Returns the current state of the port input lines. The property is not updated automatically. Manual reading of the property value in snippets is required to obtain the current input. The value can be read either to the integer or binary formats, e.g. 'string S=Input;' may return '01010101'. | | clBinaryInteger |
Triggering Input | eturns the current state of the port input lines. The property is not updated automatically. Manual reading of the property value in snippets is required to obtain the current input. The value can be read either to the integer or binary formats, e.g. 'string S=Input;' may return '01010101'. | | String |
Trigger Once | Returns the current state of the port input lines. The property is not updated automatically. Manual reading of the property value in snippets is required to obtain the current input. The value can be read either to the integer or binary formats, e.g. 'string S=Input;' may return '01010101' | | Boolean |
Runtime Status |
Is Triggered | Indicates whether the element has been triggered at least once, since activation of the parent event. Triggering occurs only in the 'Input Detection' working mode. | | Boolean |
Trigger Time | Indicates the local event time of the last element triggering. Triggering occurs only in the 'Input Detection' working mode. | | UInt64 |
+=== Properties inherited from clElement ===
Inherited properties of clElement
Name | Description | Constraints | Value Type | Upon Change |
---|
Control |
Is Enabled | If set to false the element is completely omitted when the experiment is run. | | Boolean |
|
Title | Title of the element. | | String |
|